2014年1月19日星期日

chemical oxygen self-rescuer

Product Introduction

isolation-type chemical oxygen self-rescuer is produced on the basis of the MT425-1995 standard ( starter oxygen candles of the chemical oxygen self-rescuer meet the requirements of the AQ1057,the potassium superoxide comply with the provisions of MT427-1995).
When the coal mine gas and coal dust content is very high, disasters such as explosions, fires or roadway blockagecase the environment hypoxia, or harmful, toxic gases endanger miners' lives, please worn it timely to evacuate area safely.
Mainly used for coal mine and other potentially toxic gases and asphyxiation environment.

Main Parameter

(1). Protection time( the power is 74w)
a, Labor intensity is large: the time ≧ 30min.
b, Meditation: the time ≧120min
(2). Weight
a, carry weight: ≦1.4kg; wear weight: ≦1.3kg
(3). Overall dimension: 152*112*82mm
(4). Protection performance:
a,suction temperature ≦ 55℃
b,The concentration of the airbag within a predetermined guard time is not less than 21%, the average carbon dioxide concentration is not more than 1.5%, the maximum is not greater than 3.0%, and the airbag shall not occur the phenomenon of air suction.
c,Start the device raw oxygen: 30s ≧ 2L, 60s ≧ 4L
d,Expiratory resistance and inspiratory resistance: without scrolling impact, the ventilation resistance after the protective performance test is not more than 196Mpa, after scrolling impact protection performance test airway resistance is not more than 245Mpa.

没有评论:

发表评论